{"product_id":"mercury-resistor-120-ohm-893388a01","title":"Mercury – 2-Pin Terminator \/ Resistor | CAN Network End Termination | 893388A01","description":"\u003cp data-start=\"0\" data-end=\"83\"\u003e\u003cstrong data-start=\"0\" data-end=\"83\"\u003eMercury – 2-Pin Terminator \/ Resistor | CAN Network End Termination | 893388A01\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"85\" data-end=\"88\"\u003e\n\u003cp data-start=\"90\" data-end=\"102\"\u003e\u003cstrong data-start=\"90\" data-end=\"102\"\u003eOverview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"104\" data-end=\"518\"\u003eA CAN network needs a proper end point to stay stable, and when that termination is missing, the system can act unpredictable—flickering data, random faults, or modules dropping offline. The Mercury 893388A01 Blue 2-Pin Terminator\/Resistor closes out the CAN network with the correct electrical load. It’s a small part, but it keeps the communication backbone steady so gauges and modules talk the way they should.\u003c\/p\u003e\n\u003chr data-start=\"520\" data-end=\"523\"\u003e\n\u003cp data-start=\"525\" data-end=\"541\"\u003e\u003cstrong data-start=\"525\" data-end=\"541\"\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"545\" data-end=\"640\"\u003e\n\u003cstrong data-start=\"545\" data-end=\"571\"\u003e2-Pin End Terminator –\u003c\/strong\u003e Closes out the CAN network with the correct electrical resistance.\u003c\/li\u003e\n\u003cli data-start=\"643\" data-end=\"741\"\u003e\n\u003cstrong data-start=\"643\" data-end=\"661\"\u003eBlue Housing –\u003c\/strong\u003e Identifies the specific terminator type used for its designated CAN circuits.\u003c\/li\u003e\n\u003cli data-start=\"744\" data-end=\"841\"\u003e\n\u003cstrong data-start=\"744\" data-end=\"771\"\u003eNetwork Stabilization –\u003c\/strong\u003e Helps prevent signal noise, dropped messages, and erratic behavior.\u003c\/li\u003e\n\u003cli data-start=\"844\" data-end=\"926\"\u003e\n\u003cstrong data-start=\"844\" data-end=\"866\"\u003eCAN-Ready Design –\u003c\/strong\u003e Built for termination at the end of CAN network branches.\u003c\/li\u003e\n\u003cli data-start=\"929\" data-end=\"1031\"\u003e\n\u003cstrong data-start=\"929\" data-end=\"954\"\u003eOEM Electrical Spec –\u003c\/strong\u003e Matches Mercury’s required resistance values for proper CAN communication.\u003c\/li\u003e\n\u003cli data-start=\"1034\" data-end=\"1119\"\u003e\n\u003cstrong data-start=\"1034\" data-end=\"1058\"\u003eQuick Installation –\u003c\/strong\u003e Presses into the 2-pin port securely with no tools needed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1121\" data-end=\"1124\"\u003e\n\u003cp data-start=\"1126\" data-end=\"1143\"\u003e\u003cstrong data-start=\"1126\" data-end=\"1143\"\u003eCompatibility\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1147\" data-end=\"1169\"\u003eMercury CAN networks\u003c\/li\u003e\n\u003cli data-start=\"1172\" data-end=\"1202\"\u003e2-pin CAN termination points\u003c\/li\u003e\n\u003cli data-start=\"1205\" data-end=\"1242\"\u003eEnd-of-line CAN harness connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1244\" data-end=\"1247\"\u003e\n\u003cp data-start=\"1249\" data-end=\"1285\"\u003e\u003cstrong data-start=\"1249\" data-end=\"1285\"\u003ePerformance \u0026amp; Practical Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"1287\" data-end=\"1660\"\u003eWith the correct termination in place, the CAN network behaves the way it should—steady communication, clean data, and fewer nuisance issues. This terminator helps prevent the intermittent glitches that can show up when a branch is left unterminated. It installs quickly, locks into place firmly, and provides long-term stability even in high-vibration marine environments.\u003c\/p\u003e\n\u003chr data-start=\"1662\" data-end=\"1665\"\u003e\n\u003cp data-start=\"1667\" data-end=\"1682\"\u003e\u003cstrong data-start=\"1667\" data-end=\"1682\"\u003eWhy Buy OEM\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"1684\" data-end=\"2022\"\u003eCAN systems are sensitive to incorrect resistance values. Mercury’s OEM resistor uses the exact electrical specification required for stable communication, something generic parts often fail to match. Using the OEM version prevents phantom faults, dropped data, and the kind of intermittent issues that can be difficult to diagnose later.\u003c\/p\u003e\n\u003chr data-start=\"2024\" data-end=\"2027\"\u003e\n\u003cp data-start=\"2029\" data-end=\"2036\"\u003e\u003cstrong data-start=\"2029\" data-end=\"2036\"\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"2038\" data-end=\"2228\"\u003e\u003cstrong data-start=\"2038\" data-end=\"2099\"\u003eQ1: What symptoms suggest a missing or failed terminator?\u003c\/strong\u003e\u003cbr data-start=\"2099\" data-end=\"2102\"\u003eUnstable gauge readings, intermittent drops in data, or random communication faults often point to an unterminated CAN branch.\u003c\/p\u003e\n\u003cp data-start=\"2230\" data-end=\"2370\"\u003e\u003cstrong data-start=\"2230\" data-end=\"2286\"\u003eQ2: Does this terminator work on any 2-pin CAN port?\u003c\/strong\u003e\u003cbr data-start=\"2286\" data-end=\"2289\"\u003eIt’s designed specifically for CAN termination points, not mid-chain connections.\u003c\/p\u003e\n\u003cp data-start=\"2372\" data-end=\"2448\"\u003e\u003cstrong data-start=\"2372\" data-end=\"2410\"\u003eQ3: Do I need tools to install it?\u003c\/strong\u003e\u003cbr data-start=\"2410\" data-end=\"2413\"\u003eNo. It presses directly into place.\u003c\/p\u003e\n\u003cp data-start=\"2450\" data-end=\"2569\"\u003e\u003cstrong data-start=\"2450\" data-end=\"2501\"\u003eQ4: Can this be used in saltwater environments?\u003c\/strong\u003e\u003cbr data-start=\"2501\" data-end=\"2504\"\u003eYes. The housing and contacts are built for long-term marine use.\u003c\/p\u003e\n\u003cp data-start=\"2571\" data-end=\"2742\"\u003e\u003cstrong data-start=\"2571\" data-end=\"2627\"\u003eQ5: Should this be used at both ends of the network?\u003c\/strong\u003e\u003cbr data-start=\"2627\" data-end=\"2630\"\u003eOnly at designated termination points. The system typically requires one terminator per end of the CAN backbone.\u003c\/p\u003e","brand":"Mercury","offers":[{"title":"Default Title","offer_id":46935564255523,"sku":"893388A01","price":14.61,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/7410\/9475\/files\/PV478149.jpg?v=1698794116","url":"https:\/\/partsvu.com\/en-mx\/products\/mercury-resistor-120-ohm-893388a01","provider":"PartsVu","version":"1.0","type":"link"}